PRODDUCTS
Shenzhen JHA Technology Co., Ltd is one of the leading manufacturers of hardened Ethernet, PoE, and fiber connectivity products specifically designed for harsh and demanding environments.
PRODUCTS
1.25G Single Mode 20Km DDM | Dual Fiber SFP Transceiver JHA3420D
-
- Up to 1.25Gb/s Data Links
- Hot-Pluggable
- Duplex LC connector
- Up to 20km on 9/125μm SMF
- 1310nm FP laser transmitter
- Single +3.3V Power Supply
- Monitoring Interface Compliant with SFF-8472
- Low power dissipation <1W typically
- Industrial /Extended/ Commercial operating temperature range: -40°C to 85°C/-5°C to 85°C/-0°C to 70°C Version available
- RoHS compliant and Lead Free
Classification
SFP Module
1.25G SFP
1.25G Dual Fiber
- DESCRIPTION
- DIMENSION
- ORDER INFORMATION
- DOWNLOAD
- APPLICATIONS
-
Product Introduction:
Enhance your home network with our customized Dual Fiber SFP Transceiver, the JHA3420D, specifically designed for extended reach data transmission in single mode fiber optic networks. This customized Dual Fiber SFP Transceiver is perfect for home users looking to upgrade their network capabilities for applications such as Metro/Access Networks, 1.25 Gb/s 1000Base-LX Ethernet, 1×Fibre Channel, and other optical links.
The JHA3420D customized Dual Fiber SFP Transceiver for home users features a duplex LC optics interface and is equipped with a 1310 nm FP laser for the transmitter and a PIN receiver for the receiver section. This configuration provides a robust up to 15dB link budget, ensuring reliable 1000Base Ethernet connectivity over distances up to 20km. The customized Dual Fiber SFP Transceiver for home users is a high-performance, cost-effective solution that meets the unique needs of home networking environments.
Applications:
1). Metro/Access Networks
2). 1.25 Gb/s 1000Base-LX Ethernet
3). 1×Fibre Channel
4). Other Optical Links
Description:
JHA3420D Transceiver is a high performance, cost effective module which have a duplex LC optics interface. Standard AC coupled CML for high speed signal and LVTTL control and monitor signals. The receiver section uses a PIN receiver and the transmitter uses a 1310 nm FP laser, up to 15dB link budge ensure this module 1000Base Ethernet 20km application.
• Absolute Maximum Ratings
Parameter
Symbol Min. Typical Max. Unit Storage Temperature TS
-40
+85
°C
Supply Voltage VCC
-0.5
4
V
Relative Humidity RH
0
85
%
• Recommended Operating Environment:
Parameter
Symbol Min. Typical Max. Unit Case operating Temperature Industrial TC
-40
85
°C
Extended -5
85
°C
Commercial 0
+70
°C
Supply Voltage VCC
3.135
3.465
V
Supply Current Icc
300
mA
Inrush Current Isurge
Icc+30
mA
Maximum Power Pmax
1
W
• Electrical Characteristics(TOP = -40 to 85°C, VCC = 3.135 to 3.465 Volts)
Parameter
Symbol Min. Typical Max. Unit Note Transmitter Section: Input differential impedance Rin
90
100
110
W
1
Single ended data input swing Vin PP
250
1200
mVp-p
Transmit Disable Voltage VD
Vcc – 1.3
Vcc
V
2
Transmit Enable Voltage VEN
Vee
Vee+ 0.8
V
Transmit Disable Assert Time Tdessert
10
us
Receiver Section: Single ended data output swing Vout,pp
250
800
mv
3
LOS Fault Vlosfault
Vcc – 0.5
VCC_host
V
5
LOS Normal Vlos norm
Vee
Vee+0.5
V
5
Power Supply Rejection PSR
100
mVpp
6
Note:
- AC coupled.
- Or open circuit.
- Into 100 ohm differential termination.
- 20 – 80 %
- LOS is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal detected.
- All transceiver specifications are compliant with a power supply sinusoidal modulation of 20 Hz to 1.5MHz up to specified value applied through the power supply filtering network shown on page 23 of the Small Form-factor Pluggable (SFP) Transceiver Multi-Source Agreement (MSA), September 14, 2000.
• Optical Parameters(TOP = -40 to 85°C, VCC = 3.135 to 3.465 Volts)
Parameter
Symbol Min. Typical Max. Unit Note Transmitter Section: Center Wavelength λc
1270
1310
1360
nm
Spectral Width(RMS) σRMS
3
nm
Optical Output Power Pout
-9
-3
dBm
1
Extinction Ratio ER
9
dB
Optical Rise/Fall Time tr / tf
260
ps
2
Relative Intensity Noise RIN
-120
dB/Hz
Output Eye Mask Compliant with IEEE802.3 z (class 1 laser safety) Receiver Section: Optical Input Wavelength λc
1260
1360
nm
Receiver Overload Pol
-3
dBm
4
RX Sensitivity Sen
-24
dBm
4
RX_LOS Assert LOS A
-40
dBm
RX_LOS De-assert LOS D
-25
dBm
RX_LOS Hysteresis LOS H
0.5
dB
General Specifications: Data Rate BR
1.25
Gb/s
Bit Error Rate BER
10-12
Max. Supported Link Length on 9/125μm SMF@1.25Gb/s LMAX
20
km
Total System Budget LB
15
dB
Note
- The optical power is launched into SMF.
- 20-80%.
- Jitter measurements taken using Agilent OMNIBERT 718 in accordance with GR-253.
- Measured with PRBS 27-1 at 10-12 BER
• Pin Assignment
Diagram of Host Board Connector Block Pin Numbers and Name
Diagram of Host Board Connector Block Pin Numbers and Names
• Pin Function Definitions
Pin No
Name
Function
Plug Seq
Notes
1 VeeT Transmitter Ground 1 1 2 TX Fault Transmitter Fault Indication 3 3 TX Disable Transmitter Disable 3 2 4 MOD-DEF2 Module Definition 2 3 5 MOD-DEF1 Module Definition 1 3 3 6 MOD-DEF0 Module Definition 0 3 3 7 Rate Select Not Connected 3 4 8 LOS Loss of Signal 3 5 9 VeeR Receiver Ground 1 1 10 VeeR Receiver Ground 1 1 11 VeeR Receiver Ground 1 12 RD- Inv. Received Data Out 3 6 13 RD+ Received Data Out 3 6 14 VeeR Receiver Ground 3 1 15 VccR Receiver Power 2 1 16 VccT Transmitter Power 2 17 VeeT Transmitter Ground 1 18 TD+ Transmit Data In 3 6 19 TD- Inv. Transmit In 3 6 20 VeeT Transmitter Ground 1 Notes:
- Circuit ground is internally isolated from chassis ground.
- Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.
- Should be pulled up with 4.7k – 10 kohms on host board to a voltage between 2.0V and 3.6V. MOD_DEF(0) pulls line low to indicate module is plugged in.
- Rate select is not used
- LOS is open collector output. Should be pulled up with 4.7k – 10 kohms on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
- AC Coupled
• SFP Module EEPROM Information and Management
The SFP modules implement the 2-wire serial communication protocol as defined in the SFP -8472. The serial ID information of the SFP modules and Digital Diagnostic Monitor parameters can be accessed through the I2C interface at address A0h and A2h. The memory is mapped in Table 1. Detailed ID information (A0h) is listed in Table 2. And the DDM specification at address A2h. For more details of the memory map and byte definitions, please refer to the SFF-8472, “Digital Diagnostic Monitoring Interface for Optical Transceivers”. The DDM parameters have been internally calibrated.
Table 1. Digital Diagnostic Memory Map (Specific Data Field Descriptions)

Table 2 - EEPROM Serial ID Memory Contents (A0h)
Data Address
Length
(Byte)
Name of
Length
Description and Contents
Base ID Fields 0
1
Identifier
Type of Serial transceiver (03h=SFP) 1
1
Reserved
Extended identifier of type serial transceiver (04h) 2
1
Connector
Code of optical connector type (07=LC) 3-10
8
Transceiver
11
1
Encoding
NRZ(03h) 12
1
BR, Nominal
Nominal baud rate, unit of 100Mbps 13-14
2
Reserved
(0000h) 15
1
Length(9um)
Link length supported for 9/125um fiber, units of 100m 16
1
Length(50um)
Link length supported for 50/125um fiber, units of 10m 17
1
Length(62.5um)
Link length supported for 62.5/125um fiber, units of 10m 18
1
Length(Copper)
Link length supported for copper, units of meters 19
1
Reserved
20-35
16
Vendor Name
SFP vendor name: JHA 36
1
Reserved
37-39
3
Vendor OUI
SFP transceiver vendor OUI ID 40-55
16
Vendor PN
Part Number: “JHA3420D” (ASCII) 56-59
4
Vendor rev
Revision level for part number 60-62
3
Reserved
63
1
CCID
Least significant byte of sum of data in address 0-62 Extended ID Fields 64-65
2
Option
Indicates which optical SFP signals are implemented(001Ah = LOS, TX_FAULT, TX_DISABLE all supported) 66
1
BR, max
Upper bit rate margin, units of % 67
1
BR, min
Lower bit rate margin, units of % 68-83
16
Vendor SN
Serial number (ASCII) 84-91
8
Date code
JHA’s Manufacturing date code 92-94
3
Reserved
95
1
CCEX
Check code for the extended ID Fields (addresses 64 to 94) Vendor Specific ID Fields 96-127
32
Readable
JHA specific date, read only 128-255
128
Reserved
Reserved for SFF-8079 • Digital Diagnostic Monitor Characteristics
Data Address
Parameter
Accuracy
Unit
96-97 Transceiver Internal Temperature ±3.0 °C 98-99 VCC3 Internal Supply Voltage ±3.0 % 100-101 Laser Bias Current ±10 % 102-103 Tx Output Power ±3.0 dBm 104-105 Rx Input Power ±3.0 dBm • Regulatory Compliance
The JHA3420D complies with international Electromagnetic Compatibility (EMC) and international safety requirements and standards (see details in Table following).
Electrostatic Discharge(ESD) to the Electrical Pins MIL-STD-883EMethod 3015.7 Class 1(>1000 V) Electrostatic Discharge (ESD)to the Duplex LC Receptacle IEC 61000-4-2GR-1089-CORE Compatible with standards ElectromagneticInterference (EMI) FCC Part 15 Class BEN55022 Class B (CISPR 22B)VCCI Class B Compatible with standards Laser Eye Safety FDA 21CFR 1040.10 and 1040.11EN60950, EN (IEC) 60825-1,2 Compatible with Class 1 laserproduct. • Recommended Circuit
SFP Host Recommended Circuit
• Mechanical Dimensions

Mechanical Drawing
Order Information:
Model No.
Description of Goods
Wavelength
JHA3405
1.25G Multimode Dual Fiber 550m 850nm
JHA3405D
1.25G Multimode Dual Fiber 550m DDM 850nm
JHA3420
1.25G Single Mode Dual Fiber 20Km 1310nm
JHA3420D
1.25G Single Mode Dual Fiber 20Km DDM 1310nm
JHA3440
1.25G Single Mode Dual Fiber 40Km 1310nm
JHA3440D
1.25G Single Mode Dual Fiber 40Km DDM 1310nm
JHA3480
1.25G Single Mode Dual Fiber 80Km 1550nm
JHA3480D
1.25G Single Mode Dual Fiber 80Km DDM 1550nm
JHA reserves the right to make changes to the products or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such products or information.
Published by Shenzhen JHA Technology Co., Ltd
Copyright © Shenzhen JHA Technology Co., Ltd
All Rights Reserved
*Note: Please fill in the information accurately and keep the communication unblocked. We will contact you as soon as possible
Related products